Expert in Filters,
Frequency Control Components
Design Expertise, Advanced Equipment, HIGH QUALITY
Freq Range:622MHz/1030MHz/1090MHz
Freq Range:622MHz/1030MHz/1090MHz
VCSO / SAW Oscillators
1. VCSO/SAW Oscillator 1030MHz
• SAW Frequency Stabilization
• Fundamental-Mode Oscillation at 1030.0 MHz
• Ideal for ATC/TCAS Transponder Applications
Absolute Maximum Ratings
Rating | Value | Units | |
DC Supply Voltage | +5 to +8 | VDC | |
Ambient Temperature | Powered | -40 to +70 | °C |
Storage | -40 to +70 |
Electrical Characteristics : Electrostatic Sensitive Device
Characteristic | Sym | Minimum | Typical | Maximum | Unit | |
Center Frequency | Absolute Frequency | fC | 1029.80 | 1030.00 | 1030.20 | MHz |
Tolerance from 1030.000 MHz | DfC | ±200 | kHz | |||
RF Output Power | P0 | 7 | 8 | 10 | dBm | |
DC Power Supply | Operating Voltage | Vcc | 5.0 | 6.0 | 8.0 | VDC |
Operating Current | Icc | 45 | 60 | mA | ||
Discrete Spurious | Second Harmonics | -25 | -20 | dBc | ||
Third and Higher Harmonics | -35 | -30 | ||||
Nonharmonic | <-100 | -80 | ||||
SSB Phase Noise | 1KHz Offset | -100 | -90 | dBc/Hz | ||
10KHz offset | -120 | -110 | ||||
RF Impedance | Nominal Impedance | Z0 | 50 | | ||
Operating Load VSWR | GL | 1.5:1 | ||||
Operating Ambient Temperature | TA | -45 | +85 | °C |
2. VCSO/SAW Oscillator 1090MHz
Electrical Characteristics : Electrostatic Sensitive Device
Characteristic | Sym | Minimum | Typical | Maximum | Unit | |
Center Frequency | Absolute Frequency | fC | 1089.80 | 1090.00 | 1090.20 | MHz |
Tolerance from 1090.000 MHz | DfC | ±200 | kHz | |||
RF Output Power | P0 | 7 | 8 | 10 | dBm | |
DC Power Supply | Operating Voltage | Vcc | 5.0 | 6.0 | 8.0 | VDC |
Operating Current | Icc | 45 | 60 | mA | ||
Discrete Spurious | Second Harmonics | -25 | -20 | dBc | ||
Third and Higher Harmonics | -35 | -30 | ||||
Nonharmonic | <-100 | -80 | ||||
SSB Phase Noise | 1KHz Offset | -100 | -90 | dBc/Hz | ||
10KHz offset | -120 | -110 | ||||
RF Impedance | Nominal Impedance | Z0 | 50 | | ||
Operating Load VSWR | GL | 1.5:1 | ||||
Operating Ambient Temperature | TA | -45 | +85 | °C |